ARCHITECTURE / STRUCTURE (Buildings B5, B4, B1)

  • Typical 8.1 m column grid / 1.35 m window grid
  • 2.8 m floor-to-ceiling height in buildings B1 & B5 and 3.0 m in building B4
  • Openable window modules
  • Optimized elevator waiting times and core layouts to allow efficient access for occupiers
  • Typical floor loads – 3.0 kN/sq m/office space and special reinforced 5.0 kN/sq m/storage areas
  • Suspended ceilings throughout the offices
  • 12 cm raised floors
  • Multi-tenant or single occupier efficiencies built into the design
  • Highest quality of architectural features and façades
  • Emphasis on optimal use of natural light throughout the Building
  • Excellent parking ratios and Building floor layout densities

HVAC & ELECTRICAL SYSTEM

  • 4-pipe fan coil HVAC system
  • Ceiling-mounted diffusers
  • Local temperature controllers – one per four fan coil units
  • Diverse power – two independent incoming electrical connections
  • Floor boxes – one per every 20 sq m for 2 workstations
  • Office lighting – fully recessed fluorescent luminaries to fulfill local code to open plan layout
  • Space allowance for tenant generators and diverse electrical distribution
  • Efficient distribution of services to allow Tenant specific IT/Lan rooms

FIRE DETECTION & SECURITY SYSTEM

  • Sprinkler system possible throughout the complex
  • Smoke Detection System
  • Automatic Link to the fire brigade
  • Fire hoses reels or hydrants
  • Building Management System
  • CCTV monitoring of all access points to the Buildings and parking areas
  • Access Control System
  • Security Staff available 24h a day

TELECOMMUNICATION

  • Fiber-optic and analogue wires from two independent operators
  • Main distribution frame
  • Fully digital central telephone switch
  • Diverse routed telecoms distribution